Voodoo Scenario Steps: Screen Data

Screen Data Extraction

In this step, data is extracted. The area on the screen must be selected for data extraction.

  • General Information
  • Parameter Description
    Name The name of screen data extraction step. (Compulsory)
    Description The description of screen data extraction step. (Not Compulsory)
  • Region
  • Parameter Description
    Related Flow Image The using image during this step. (Compulsory)
    Region Of Interest Select the region to click or wait. (Compulsory)
    Region of Interest Search Options Set the image search level as Normal, Sensitive, Very Sensitive and select the image to search option. (Compulsory)
    Image Search Level Choose the sensitivity level of selected pattern if you want to search as image.
    Image To Search Search the pattern as Selected Image or Image From File System (eg. A file path can be given to click ‘…’ button. Can be given as ‘Constant’ or ‘Data’)
    Region Of Interest Validation Options Select the text validation option as Yes or No. (Compulsory)
    Text Validation If No is chosen, text verification will not realized. If Yes option is chosen, you write the accurate text with whole characters and you can chose the sensitivity level.
  • Action
  • Parameter Description
    Region Selection Method Region selection is made on the screen.

    From Selected Region Data is extracted from the selected region.
    From the Perimeter of The Selected Region Indicates that data will be extracted from the second region to be selected according to the region on the screen.
  • Time Settings
  • Parameter Description
    Maximum Step Duration The maximum time to the end of completion to find the image. If the image cannot found on the screen or the selected region, this step will not verified. (Compulsory)
    Wait Duration After Operation The wait time to pass next step to find the image. (Compulsory)
  • Scenario Flow
  • Parameter Description
    Step Flow Indicates the step flow type. (Compulsory)

    Ordered The flow type to continue sequentially.
    Conditional The flow type to continue conditionally.

    • Step to Run On Success
    • This step turns to another step on success. You can choose End to terminate the scenario step.

    • Step To Tun On Fail
    • This step turns to another step on fail. You can choose End to terminate the scenario step.

    Screen Data Search

    It is used for searching or typing data in the field selected at this step.

    • General Information
    • Parameter Description
      Name The name of screen data search step. (Compulsory)
      Description The description of screen data search step. (Not Compulsory)
    • Region
    • Parameter Description
      Related Flow Image The using image during this step. (Compulsory)
      Region Of Interest Select the region to click or wait. (Compulsory)
      Region of Interest Search Options Set the image search level as Normal, Sensitive, Very Sensitive and select the image to search option. (Compulsory)
      Image Search Level Choose the sensitivity level of selected pattern if you want to search as image.
      Image To Search Search the pattern as Selected Image or Image From File System (eg. A file path can be given to click ‘…’ button. Can be given as ‘Constant’ or ‘Data’)
      Region Of Interest Validation Options Select the text validation option as Yes or No. (Compulsory)
      Text Validation If No is chosen, text verification will not realized. If Yes option is chosen, you write the accurate text with whole characters and you can chose the sensitivity level.
    • Action
    • Parameter Description
      Related Region Selection Indicates that data will be searched from the selected area. The data type to be searched can be selected as text or picture.Text value to search; can be chosen from constant, variable, or data source. If a fixed word is to be selected, only one word must be entered. If Turkish characters are used in the interface language, Turkish must be selected.
      Search Result Data Field If desired, the values ​​found can be written to a variable.
      Related Region If selected, the related region marked according to the found word is thrown to the selected region (it can be used in other steps from here). If it is not selected, key click operations are performed.
      Action Key click operations are performed.
    • Time Settings
    • Parameter Description
      Maximum Step Duration The maximum time to the end of completion to find the image. If the image cannot found on the screen or the selected region, this step will not verified. (Compulsory)
      Wait Duration After Operation The wait time to pass next step to find the image. (Compulsory)
    • Scenario Flow
    • Parameter Description
      Step Flow Indicates the step flow type. (Compulsory)

      Ordered The flow type to continue sequentially.
      Conditional The flow type to continue conditionally.

      • Step to Run On Success
      • This step turns to another step on success. You can choose End to terminate the scenario step.

      • Step To Tun On Fail
      • This step turns to another step on fail. You can choose End to terminate the scenario step.

      Input Dialog Box

      In special cases where data is entered on the screen (such as sms password entry), the user creates an interface to enter information and allows the robot to write the entered value on the screen. The user can edit the design of the information entry screen to be opened as required.

      • General Information
      • Parameter Description
        Name The name of screen input dialog box step. (Compulsory)
        Description The description of screen input dialog box step. (Not Compulsory)
      • Region
      • Parameter Description
        Related Flow Image The using image during this step. (Compulsory)
      • Action
      • Parameter Description
        Property It is the menu where the properties of the dialog box to be created on the screen are created.

        • Label
        • It is the field where the text of the description label and its coordinates on the form are specified in the data entry dialog box form.

        • Text Box
        • It ensures that the value entered in the data entry dialog box is jumped to the data field in the specified data source.

        • Form
        • Specifies the form name at the top of the data entry dialog box form.

        • Ok Button
        • Indicates the location of the OK button.

        • Cancel Button
        • Indicates the location of the cancel button.

      • Action
      • Parameter Description
        Property It is the menu where the properties of the dialog box to be created on the screen are created.
        Form Properties It is the field where the text of the description tag and its coordinates on the form are specified.Allows the value entered in the data entry dialog to be thrown into the data field in the specified data source.
      • Time Settings
      • Parameter Description
        Maximum Step Duration The maximum time to the end of completion to find the image. If the image cannot found on the screen or the selected region, this step will not verified. (Compulsory)
        Wait Duration After Operation The wait time to pass next step to find the image. (Compulsory)
      • Scenario Flow
      • Parameter Description
        Step Flow Indicates the step flow type. (Compulsory)

        Ordered The flow type to continue sequentially.
        Conditional The flow type to continue conditionally.

        • Step to Run On Success
        • This step turns to another step on success. You can choose End to terminate the scenario step.

        • Step to Run On Fail
        • This step turns to another step on fail. You can choose End to terminate the scenario step.